Part E Acoustic Performance Standards
Airborne and impact sound insulation requirements for separating walls and floors, referencing Approved Document E: Resistance to the Passage of Sound (2003 edition incorporating 2004, 2010, 2013, and 2015 amendments).
Minimum Performance Standards (AD-E Table 0.1a & 0.1b)
| Element | Test Parameter | New Build | Conversion |
|---|---|---|---|
| Separating wall (airborne) | DnT,w + Ctr | ≥ 45 dB | ≥ 43 dB |
| Separating floor (airborne) | DnT,w + Ctr | ≥ 43 dB | ≥ 43 dB |
| Separating floor (impact) | L'nT,w | ≤ 64 dB | ≤ 64 dB |
| Wall between dwelling and common area (airborne) | DnT,w + Ctr | ≥ 43 dB | ≥ 43 dB |
| Floor between dwelling and common area (airborne) | DnT,w + Ctr | ≥ 43 dB | ≥ 43 dB |
Internal Walls and Floors Within a Dwelling (AD-E Section 3)
| Element | Requirement |
|---|---|
| Walls between bedrooms and bathrooms/WCs | Good practice guidance only (no statutory minimum) |
| Floors between rooms in dwellings formed by conversion | Rw ≥ 40 dB recommended |
| Walls between rooms and refuse chutes/lifts | See AD-E Section 4 for specific guidance |
Pre-Completion Testing (PCT) Requirements
| Requirement | Detail |
|---|---|
| When required | All new-build dwellings unless using Robust Details |
| Test standard | BS EN ISO 16283 (replaced BS EN ISO 140) |
| Sample rate (first dwelling type) | 1 set of tests per dwelling type per site |
| If test fails | Remedial work required, then re-test |
| Tester accreditation | UKAS-accredited or registered with ANC/ATTMA scheme |
Related Calculators
Use the Sound Insulation Calculator for estimating acoustic performance. See the Part E Sound Reduction page for wall and floor construction specifications.
Always check the latest edition of Approved Documents on the Planning Portal (planningportal.co.uk) as regulations are updated periodically.
How We Calculate This
Frequently Asked Questions
Related Calculators
Concrete Mix Ratios
Standard UK concrete mix ratios explained with quantities per cubic metre and guidance on when to use each.
Insulation U-Values
Part L target U-values for walls, floors, roofs and windows with insulation thicknesses to achieve compliance.
UK Brick Dimensions
Standard UK brick sizes, coordinating dimensions and bricks per square metre for common bond patterns.
UK Cable Sizes
BS 7671 cable sizes and current ratings for common UK domestic circuits and installations.
Last updated: April 2026
All calculations are estimates. Verify with your supplier.