UK Soil Pipe Sizes & Gradients
110 mm standard, 82 mm and 160 mm soil pipe sizes with connection types, gradient requirements and installation guidance.
Standard Soil Pipe Sizes
| Nominal Size (mm) | Outside Diameter (mm) | Application | Standard Lengths |
|---|---|---|---|
| 82 | 82.4 | Waste-only stacks, vent pipes | 3 m, 4 m |
| 110 | 110 | Standard soil stack, WC connections | 3 m, 4 m |
| 160 | 160 | Large buildings, multiple WCs | 3 m, 6 m |
Connection Types
| Type | Joint Method | Pros | Cons |
|---|---|---|---|
| Push-fit (ring seal) | Rubber O-ring seal | Easy, allows movement, demountable | Slightly bulkier sockets |
| Solvent weld | Solvent cement adhesive | Neat, slim profile, rigid | Permanent, no movement allowance |
| Boss connector | Strap-on or solvent boss | Connects waste pipes to existing stack | Must be correctly positioned |
Branch Connection Gradients (Approved Document H)
| Branch Type | Pipe Size | Min. Gradient | Max Length |
|---|---|---|---|
| WC branch | 110 mm | 1:40 (min 18 mm/m) | 6 m |
| Basin branch | 32 mm | 1:12 to 1:40 | 1.7 m (unventilated) |
| Bath/shower branch | 40 mm | 1:12 to 1:40 | 3 m (unventilated) |
| Kitchen sink branch | 40 mm | 1:12 to 1:40 | 3 m (unventilated) |
Related Calculators
See the Drainage Pipe Sizes for underground drainage, or the Trap Sizes for waste trap specifications.
How We Calculate This
Frequently Asked Questions
Related Calculators
Concrete Mix Ratios
Standard UK concrete mix ratios explained with quantities per cubic metre and guidance on when to use each.
Insulation U-Values
Part L target U-values for walls, floors, roofs and windows with insulation thicknesses to achieve compliance.
UK Brick Dimensions
Standard UK brick sizes, coordinating dimensions and bricks per square metre for common bond patterns.
UK Cable Sizes
BS 7671 cable sizes and current ratings for common UK domestic circuits and installations.
Last updated: April 2026
All calculations are estimates. Verify with your supplier.