Noise Assessment Calculator
Estimate construction noise levels at a receiver position, accounting for distance attenuation, barriers and on-time percentage. Based on BS 5228.
From noise source to nearest property
Fraction of the daytime period the plant actually operates (BS 5228 on-time)
Length of the daytime assessment period (descriptive — does not change LAeq)
Solid hoarding or earth bund between source and receiver
5-10 for hoarding, 10-15 for earth bund
Next up: related pages
How We Calculate This
This calculator estimates the daytime LAeq at a receiver position using the stationary-plant method of BS 5228-1:2009+A1:2014 Annex F: an indicative activity sound level, distance attenuation for a point source, an optional barrier correction, and a single percentage-on-time correction.
The formula
Attenuation = 20 × log10(Distance ÷ Reference distance)
Level at receiver = Source dB − Attenuation − Barrier
LAeq = Level + 10 × log10(On-time % ÷ 100)
There is only one time term. In BS 5228 the on-time percentage is already defined relative to the daytime assessment period (e.g. a breaker running 5 h of a 10 h day = 50%), so +10 × log10(on-time ÷ 100) alone converts the level-while-operating into the period LAeq. The working-hours figure is descriptive only and does not rescale the result.
For a concrete breaker at 95 dB(A) at 10m, receiver at 50m, 10 dB barrier, 50% on-time: attenuation = 14 dB, level = 95 − 14 − 10 = 71 dB, LAeq = 71 − 3 = 68 dB(A).
Indicative noise levels (BS 5228-1 Annex C/D)
Representative figures only — always use the measured or manufacturer level for the specific plant. Impact (percussive) piling in Annex C ranges widely, roughly 95–120 dB(A) at 10m.
- Circular saw: 100 dB(A) at 1m
- Impact (percussive) piling: ~105 dB(A) at 10m
- Concrete breaking: 95 dB(A) at 10m
- Demolition: 85 dB(A) at 10m
- Bored / CFA piling: ~85 dB(A) at 10m
- General construction: 75 dB(A) at 10m
Frequently Asked Questions
There is no single legal limit, but local authorities typically set daytime limits of 65-75 dB(A) LAeq at the nearest noise-sensitive receiver. BS 5228 provides guidance values: 65 dB for low ambient areas, 70 dB for suburban, and 75 dB for urban/industrial areas. Work outside permitted hours (usually 08:00-18:00 Mon-Fri, 08:00-13:00 Sat) is generally not allowed.
For a point source, noise decreases by approximately 6 dB for every doubling of distance. So if a concrete breaker is 95 dB at 10m, it will be approximately 89 dB at 20m, 83 dB at 40m, and 77 dB at 80m. This is the inverse-square law. Line sources (e.g., traffic) decrease by only 3 dB per doubling of distance.
A solid construction site barrier (2.4m high hoarding) typically reduces noise by 5-15 dB depending on its height relative to the line of sight between source and receiver. A barrier that just breaks the line of sight gives about 5 dB reduction. Higher barriers or earth bunds can achieve 10-15 dB. The barrier must have no gaps to be effective.
Under Section 61 of the Control of Pollution Act 1974, a contractor can apply to the local authority for prior consent for construction works. This sets agreed noise levels, working hours, and best practicable means (BPM) of noise control. Having Section 61 consent provides a defence against prosecution under Section 60 noise nuisance notices.
On-time percentage is the proportion of the daytime assessment period during which the plant actually operates. For example, a concrete breaker running 5 hours in a 10-hour day is 50% on-time. Because the percentage is already defined relative to the assessment period, BS 5228 applies a single correction of 10 × log10(on-time/100) to convert the level-while-operating into the period LAeq — so 50% on-time lowers the LAeq by 3 dB versus continuous running. There is no separate adjustment for the length of the working day; the working-hours figure here is descriptive only.