Radon Protection Calculator — Membrane, Sump & Ventilation
Calculate radon protection requirements based on BRE radon risk area. Covers membrane area with laps, sump kits, and joint tape quantities.
Total ground floor footprint
Total perimeter length
Sump + 110mm vent stack — part of full protection (over 10%)
Standard 4m width
UK radon rolls are 20m (4×20m = 80 m²)
Minimum 150mm overlap (BR 211)
Next up: related pages
How We Calculate This
This calculator determines radon protection materials based on floor area and the level of protection required. It calculates membrane area including laps and upstands, joint tape, and sump kit quantities.
The formula
Membrane area = (Floor area + Perimeter upstand) × Lap factor
Rolls = Ceiling(Membrane area ÷ Roll coverage)
Joint tape = Perimeter + Internal joints
Sump kits = 1 per 250 m² floor area (full protection)
The lap factor allows for the 150mm side laps required by BR 211, plus roughly 6% for end laps and cutting waste (about 10% over the net area at a 4m roll width). UK radon barriers (Visqueen Radon R400, Novia 1600G, Permagard) are supplied on 4m × 20m rolls = 80 m² each.
For example, 80 m² floor with 36m perimeter: Upstand = 36 × 0.15 = 5.4 m². Membrane = (80 + 5.4) × 1.10 = 93.9 m². At 4m × 20m rolls (80 m²) = Ceiling(93.9 ÷ 80) = 2 rolls. Tape: 36 + 20 = 56m = 2 rolls. 1 sump kit for full protection.
The 1-sump-per-250 m² figure is BRE’s best case for a single sump in clean, permeable fill (influence radius about 9m). Less permeable or lower-quality ground needs sumps at 100–200 m² spacing — confirm the layout with Building Control and the membrane manufacturer.
Frequently Asked Questions
Check the UK Radon Map at ukradon.org or request a report from the British Geological Survey. If 3-10% of homes in the area exceed the action level (200 Bq/m³), basic protection (membrane only) is required. If more than 10% exceed it, full protection (membrane + sump) is needed. Building Control will specify the requirement based on the postcode.
Basic protection uses a gas-resistant membrane across the ground floor with sealed joints and upstands — sufficient for lower risk areas. Full protection adds a radon sump (a void beneath the floor slab connected to an external vent pipe) which can be activated with an electric fan if radon levels remain high after occupation. Full protection is required in higher-risk areas.
The membrane must comply with BS 8485 and BRE Report 211. It should be a minimum 1200 gauge (300 micron) polyethylene or purpose-made radon barrier. Visqueen Radon Membrane and Proofex Engage are popular UK choices. The membrane must be continuous, with all joints lapped by at least 150mm and sealed with proprietary tape. Penetrations must be sealed with top-hat details.
A radon sump is a void formed in the permeable fill beneath the ground floor slab — a proprietary unit (e.g. Visqueen Radon Sump, roughly 700 × 700 × 250mm) or a hand-built gravel-filled void. It connects to a 110mm pipe that rises through the building and exits above the roof. In passive mode the stack effect draws radon from beneath the slab and vents it safely above roof level; one sump typically protects about 150–250 m² depending on fill permeability. If levels are still high after testing, an in-line fan is added to the pipe to actively extract the radon.
Test radon levels 6-12 months after occupation, once the building is sealed and heated. Use a pair of validated passive detectors (one in the living area, one in a bedroom) for the full 3-month measurement period — UKHSA's UKradon Home Measurement Pack costs £52.80 inc VAT and includes both detectors and a pre-paid return envelope. The UK action level is 200 Bq/m³ (target level 100 Bq/m³). If results exceed the action level, fit or activate the in-line fan on the sump and re-test.
Related Calculators
Was this calculator helpful?
Last updated: March 2026
Verified against UK standards · estimates only, confirm with your supplier.