Combi Flow Rate Calculator — Litres Per Minute
Calculate combi boiler hot water flow rate at different temperature rises. Check if a combi can meet simultaneous outlet demand.
ΔT you need; 35°C is the common quoting basis, 40-45°C for worst-case winter
Cold mains water temperature
Number of outlets running at once
Leave at 1.0 for rated DHW output (manufacturer specs are already net)
Next up: related pages
How We Calculate This
This calculator determines the hot water flow rate a combi boiler can deliver at various temperature rises, helping assess whether it can meet the property's demand.
Formula
- Flow rate (L/min): (kW × 60) ÷ (4.186 × ΔT), where 4.186 kJ/kg·K is the specific heat of water
- Common quoting basis: 35°C rise (10°C in to 45°C out) — the most common UK manufacturer convention, but some specs use 30°C or 40°C, so check the data badge
- Summer: ~25°C rise gives higher flow
- Winter: ~45°C rise gives lower flow
- Effective kW: Rated DHW kW × derating factor
Working figures for this are collected in our Flow Rate Conversions reference table.
Frequently Asked Questions
Flow rate (L/min) = (kW × 60) ÷ (4.186 × ΔT), where 4.186 kJ/kg·K is the specific heat of water — this is standard heat-balance physics (Q = mass flow × specific heat × temperature rise), not a single Building Regulation clause. For a 30 kW combi at 35°C rise: (30 × 60) ÷ (4.186 × 35) = 12.3 L/min. A 35°C rise is the most common UK manufacturer quoting basis (10°C cold in → 45°C hot out), but some specs quote at 30°C or 40°C — always check the temperature rise printed on the data badge before comparing models.
A comfortable shower needs 8–12 litres per minute. A power shower or rainfall head may need 12–15 L/min. A 28–30 kW combi delivers about 11–12 L/min at 35 °C rise, which is adequate for one shower. Running a second outlet simultaneously will reduce flow to each. Check your available pressure with our Water Pressure Calculator.
Generally no. A standard 30 kW combi delivers about 12 L/min at 35 °C rise, which would split to only 6 L/min per shower — below the minimum for a comfortable shower. For two simultaneous showers, consider a 40+ kW combi or a system boiler with stored hot water. Use our Boiler Size Calculator to compare options, or our Hot Water Cylinder Calculator if switching to stored hot water.
Most combi boilers fire when the DHW flow switch detects roughly 2-3 L/min, though the exact flow-switch threshold is model-specific (typically around 1-2.5 L/min) and is rarely printed on the data badge — check the manufacturer manual if in doubt. If your flow rate is too low (e.g. from partially closed taps or restrictive showerheads), the boiler may not fire. Some models set DHW activation higher, around 3.5 L/min.
Yes significantly. In summer, incoming mains water may be 15-18°C, needing only a 25-30°C rise — giving higher flow rates. In winter, mains water drops to 5-8°C, requiring a 40-45°C rise and reducing flow rate. Always size for worst-case winter conditions.