Condensate Pipe Calculator — Boiler Drainage
Calculate maximum condensate pipe runs, minimum fall, external insulation requirements, and termination options per BS 6798 and Building Regulations.
Total horizontal pipe run
Condensate pipe outer diameter
Boiler rated output
Where condensate pipe discharges
Does the pipe run outside the building?
How We Calculate This
This calculator helps plan condensate pipe installations for condensing boilers in accordance with BS 6798 and manufacturer guidance. It checks run lengths, fall requirements, and external installation compliance.
Key rules
- Maximum run: 3m (21.5mm), 6m (32mm), 10m (40mm)
- Minimum fall: 2.5° (~44mm/m)
- External runs: Minimum 32mm, insulated, keep short
- Condensate rate: ~2L/hr per 30 kW condensing boiler
- Termination: Soil stack, trapped gulley, or limestone soakaway