Eaves Ventilation Calculator — BS 5250 Compliance
Calculate eaves ventilation to BS 5250: 10mm continuous gap or equivalent, soffit vent count, over-fascia ventilators and ridge vent pairing.
Combined eaves run (both sides)
Determines ventilation requirement
Method of providing ventilation
How We Calculate This
This calculator determines the eaves ventilation provision needed to comply with BS 5250 (Management of moisture in buildings).
The formula
Required free area = Eaves length × Continuous gap (mm)
Circular vents = Required free area ÷ Individual vent area
BS 5250 requirements
- Cold pitched roof: 10mm continuous at eaves + 5mm at ridge
- Lean-to / mono-pitch: 10mm at both high and low ends
- Flat/warm roof: Ventilated batten counter above membrane