Basement Ventilation Calculator
Calculate ventilation rates per Approved Document Part F for habitable basement rooms. Determines if mechanical ventilation is required and sizes ductwork and lightwells.
Basement room floor area
Floor to ceiling height
Determines required extract rate
Maximum occupancy for this room
Via lightwell or above ground level
Select mechanical ventilation type
How We Calculate This
This calculator determines ventilation requirements for basement rooms per Approved Document F (Ventilation) of the Building Regulations for England. It considers room use, occupancy, and whether natural ventilation via windows is available.
Ventilation rates
Habitable rooms: 8 L/s per occupant (minimum 13 L/s) for continuous mechanical ventilation, or equivalent air changes per hour.
Wet rooms: Kitchens require 60 L/s intermittent extract (or 13 L/s continuous). Bathrooms require 15 L/s intermittent (or 8 L/s continuous).
System selection
If openable windows are present (via lightwell), natural ventilation with trickle vents may suffice. Otherwise, mechanical ventilation is required — MVHR is recommended for energy efficiency and comfort. Duct sizing maintains air velocity below 3 m/s to control noise levels.
Frequently Asked Questions
Related Calculators
Basement Conversion Cost Calculator
Estimate basement conversion cost per m² by type: tanking, lowered floor or new-build.
Basement Underpinning Calculator
Calculate basement underpinning pin sequence, mass concrete volume and bay count.
Basement Waterproofing Calculator
Calculate basement waterproofing materials for Type A, B or C systems.
Basement Sump Pump Calculator
Size basement sump pump from inflow rate with chamber volume and battery backup.
Basement Staircase Calculator
Calculate basement staircase going, headroom and Part K compliance.
Last updated: March 2026
All calculations are estimates. Verify with your supplier.