Basement Waterproofing Calculator
Calculate waterproofing material quantities for Type A (tanking slurry), Type B (structural concrete), or Type C (cavity membrane with sump pump) systems per BS 8102.
Total internal basement wall area
Internal basement floor area
Typically 2-3 coats
Per coat — PRODUCT-SPECIFIC: ~1.0–1.5 kg/m² for low-pressure/Sika Brushcoat-class, 2–3 kg/m² for standard grey tanking slurries (Permagard PermaSEAL, Sika DPS). Read your product PDS.
Type B walls — typically 250–300 mm (BS EN 1992-3)
Type B slab — typically 200–300 mm (BS EN 1992-3)
Type C cavity drain membrane cost
Type A tanking slurry cost
Next up: related pages
How We Calculate This
This calculator determines material quantities for the three main basement waterproofing systems defined in BS 8102:2022 (Code of Practice for Protection of Below Ground Structures Against Water).
Type A — Tanking
Cementitious slurry is applied in multiple coats to wall and floor surfaces. Quantity = total area × coverage rate (kg/m²) × number of coats. The coverage rate is product-specific: around 1.0–1.5 kg/m² per coat for low-pressure / Sika Brushcoat-class slurries, and 2–3 kg/m² per coat for standard grey tanking slurries (e.g. Permagard PermaSEAL). Always use the rate on your chosen product's data sheet.
Type B — Structural
Reinforced concrete designed to be waterproof in itself (watertight construction per BS EN 1992-3). Wall and slab thickness are both inputs — typically 250–300 mm walls and 200–300 mm slabs. Concrete volume = (wall area × wall thickness) + (floor area × slab thickness).
Type C — Drained
Cavity drain membrane (studded HDPE sheet) is fixed to walls and floor with a channel drain at the perimeter collecting water to a sump pump. Membrane area includes a 10% overlap allowance. The channel-drain length is estimated from the floor area assuming a square room (perimeter = 4 × √area); for long, narrow basements the true wall-to-floor perimeter is larger, so add roughly 10–20% to the figure shown.
Frequently Asked Questions
BS 8102:2022 defines three types: Type A (barrier or tanking) applies a waterproof coating to the structure; Type B (structural integral) uses specially designed reinforced concrete that is inherently waterproof; Type C (drained protection) uses a cavity drain membrane system that manages water ingress by directing it to a sump pump. Each has different applications, and combining systems provides the highest protection grade.
Type C (cavity drain membrane) is the most commonly used system for basement conversions in the UK because it works with water pressure rather than against it, is forgiving of minor structural defects, and can be installed without external excavation. BS 8102 recommends combining two systems (e.g. Type A + Type C) for habitable basements to achieve Grade 3 (dry) protection.
A cementitious tanking slurry (Type A) is applied in at least 2 coats, but the coverage rate is product-specific. Low-pressure and Sika Brushcoat-class products are around 1.0–1.5 kg/m² per coat, whereas standard grey tanking slurries (e.g. Permagard PermaSEAL 2–3 kg/m², Sika Damp Proofing Slurry ~2.1 kg/m²/mm) use roughly double. For 3 coats at 1.5 kg/m² over 100m² of wall and floor you would need 450 kg; the same area in a 2-coat grey slurry at 2.5 kg/m² needs 500 kg. Always follow the manufacturer's specific application rate from the product data sheet. The substrate must be clean, sound, and dampened before application.
Yes, Type C cavity drain membrane systems always require at least one sump chamber with a submersible pump to discharge collected water. BS 8102:2022 does not set a fixed sump volume — the sump and pump must be sized for the worst-case water ingress and be fully maintainable. For habitable (Grade 3) basements it advises a dual-pump arrangement with battery backup and a high-water-level alarm, which in practice is treated as a requirement. For larger basements, additional sumps may be needed. Sizing should always follow the waterproofing designer's calculation and the pump manufacturer's data.
A properly installed waterproofing system should last the lifetime of the building. Type A tanking has a typical design life of 30+ years. Type B structural concrete is permanent but relies on the concrete remaining uncracked. Type C membrane systems have mechanical components (pumps) that need replacing every 5-10 years, but the membrane itself is lifetime-rated.
Related Calculators
Basement Underpinning Calculator
Calculate basement underpinning pin sequence, mass concrete volume and bay count.
Basement Ventilation Calculator
Calculate basement ventilation per Part F with mechanical or lightwell natural options.
Basement Staircase Calculator
Calculate basement staircase going, headroom and Part K compliance.
Was this calculator helpful?
Last updated: March 2026
Verified against UK standards · estimates only, confirm with your supplier.