PIV Unit Calculator — Positive Input Ventilation Sizing

Size a Positive Input Ventilation unit based on house volume and air changes, with heater option for cold draught prevention and running costs.

Total internal volume of house

Storeys including ground

Heater Option

Tempers cold incoming air

PIV unit installed cost

How We Calculate This

This calculator sizes a PIV unit based on house volume and target air change rate.

The formula

Required Flow (m³/hr) = House Volume × Air Changes per Hour

Fan cost = (Fan Watts / 1000) × 24 × 365 × £0.2611/kWh (Ofgem price cap unit rate, 1 Jul–30 Sep 2026). The fan runs continuously, drawing roughly 6–15 W depending on unit size.

The optional heater is thermostatically controlled — it only modulates on when the incoming loft/outside air is cold (around 6°C), so it does not run at full power around the clock. We model it as roughly 3 equivalent full-power hours per day across about 150 cold days, which matches the manufacturer-published heated running costs (EnviroVent quote a heated PIV at around £52/year against £8/year unheated — a heater increment of roughly £30–£60/year for a 400 W unit).

Unit sizes

  • Small: Up to 60 m³/hr (1-2 bed flat)
  • Medium: Up to 120 m³/hr (3 bed house)
  • Large: Up to 200 m³/hr (4+ bed house)

Frequently Asked Questions

Was this calculator helpful?

Last updated: March 2026

Verified against UK standards · estimates only, confirm with your supplier.