Extension Fire Safety Calculator — Part B Compliance
Determine Approved Document B means-of-escape requirements for two-storey extensions and loft conversions: when a protected stairway is required, fire doorsets, mains-powered smoke alarms and escape windows.
Storeys in the existing house before the work (basement excluded).
New first-floor habitable rooms — each needs an emergency escape window to AD B para 2.10.
Only used when a protected stairway is required (loft / 3-storey). Each such room needs a min E 20 (FD20) fire doorset.
Next up: related pages
How We Calculate This
This calculator applies Approved Document B Volume 1 (Dwellings) Section 2 means-of-escape rules, keyed off whether a storey floor is more than 4.5m above ground.
Key requirements
- Protected stairway: mandatory only when a storey is above 4.5m (loft / 3 storeys, para 2.5). Two-storey work has a choice of escape windows or a protected stairway (para 2.2)
- Fire doorsets: minimum E 20 (FD20; FD30 in practice) on rooms opening onto a protected stairway. AD B Vol 1 does not require a self-closer or cold smoke seal on these doors in a single-family house (other than the integral-garage door)
- Smoke/heat alarms: mains-powered, interlinked, Grade D1 Category LD2 (min LD3, §1.1) to BS 5839-6 — escape route per storey + kitchen heat alarm
- Escape windows: 0.33 m² minimum openable area, ≥450mm each dimension, bottom of opening ≤1100mm above floor (para 2.10)
Based on Approved Document B (fire safety) Volume 1: Dwellings — 2019 edition incorporating the 2020, 2022 and 2025 amendments (collated with the 2026 and 2029 amendments). Always confirm with your Building Control body for your specific layout.
Frequently Asked Questions
Not necessarily. For a two-storey dwellinghouse the first floor is no more than 4.5m above ground, and AD B Vol 1 para 2.2 gives a CHOICE: each first-floor habitable room (kitchens excepted) needs EITHER an emergency escape window/external door (para 2.10) OR direct access to a protected stairway. Escape windows are the common solution — a protected stairway is an acceptable optional alternative, not a requirement. A protected stairway only becomes mandatory once a storey floor is MORE than 4.5m above ground (three storeys / a loft conversion), under para 2.5.
Where a protected stairway IS required (3 storeys / loft, para 2.5/2.21), AD B Vol 1 specifies fire doorsets of minimum E 20 — historically an FD20 door. Because certifiers (BWF, BM TRADA) no longer certify FD20 doors, FD30 is fitted in practice. Crucially, in a single-family dwellinghouse AD B Vol 1 does not require these fire doors to be self-closing (other than a door between the house and an integral garage), and there is no requirement for cold smoke seals (the 'S' designation) — the self-closer and smoke-seal rules apply to flats and HMOs, not houses. This interpretation was long set out in the (now-withdrawn) BCA Technical Guidance Note 9, but it follows directly from Approved Document B Volume 1 itself, so the position is unchanged. Always confirm the detail with your Building Control body.
AD B Vol 1 Section 1 (§1.1) requires at least a Grade D2 Category LD3 system to BS 5839-6; for new habitable rooms and loft conversions, Building Control practice is Grade D1 Category LD2. Smoke alarms should be mains-powered (BS EN 14604) with a battery standby supply, sited on the escape route (hall plus each landing), with a heat alarm (BS 5446-2) in the kitchen and a smoke alarm in the principal habitable room, all interlinked so one trigger sounds all. A system is required under §1.8 where a new habitable room is created above or below the ground storey. Battery-only alarms are not acceptable for new work.
On a two-storey dwellinghouse, yes — an emergency escape window is the primary escape strategy for first-floor habitable rooms (AD B para 2.2/2.10) unless you instead provide direct access to a protected stairway. The window must have an unobstructed openable area of at least 0.33 m², a minimum 450mm height AND 450mm width, with the bottom of the opening no more than 1100mm above the floor. Locks (with removable keys) and child-resistant opening stays ARE permitted (para 2.10c), and the window must be able to remain open without being held (para 2.10d).
A loft conversion creates a storey above 4.5m, so it carries the fuller requirements (AD B para 2.21): a protected stairway from the ground floor to the loft separated by fire-resisting construction (minimum REI 30), fire doorsets of minimum E 20 (FD20, in practice FD30) on rooms opening onto the stairway with existing doors upgraded where necessary, mains-powered interlinked smoke/heat alarms on every level, and escape provision for loft rooms. An open-plan alternative (para 2.23) allows sprinklers to BS 9251 plus a REI 30 partition / E 20 door separating ground from upper storeys and REI 30 around cooking, instead of fully enclosing the stair.