Loft Fire Safety Calculator
Calculate fire safety requirements and costs for loft conversions per Approved Document B. Covers protected routes, fire doors, alarms, escape windows and sprinklers.
How We Calculate This
This calculator estimates the fire safety upgrades needed for a loft conversion per Approved Document B.
Requirements
Protected stairway + Fire doors + LD2 alarm + Escape windows
- All doors onto stairway: FD30 (existing) or FD30 (new)
- 30-minute fire-resistant lining to stairway walls and ceiling
- Interlinked mains smoke detectors (LD2)
- Escape window in each loft room (≥0.33m², min 450mm)
- Sprinklers if open-plan ground floor