Loft Fire Safety Calculator

Calculate fire safety requirements and costs for loft conversions per Approved Document B. Covers protected routes, fire doors, alarms, escape windows and sprinklers.

Usable loft area (sizes any sprinkler estimate)

Habitable rooms in the loft

Before loft conversion

FD20 doorset, supply and install (estimate)

Safety notice

Fire safety measures must satisfy Approved Document B and often need building control approval. Confirm the final specification with building control or a fire engineer before relying on it.

How We Calculate This

This calculator estimates the fire-safety upgrades for a loft conversion that adds a storey more than 4.5m above ground, following Approved Document B Vol 1 (2019 edition incorporating 2020/2022 amendments), §2.21–2.23.

Standard solution — enclosed protected stairway (§2.21)

  • All doors onto the stairway: FD20 (E20) minimum — Table C1, item 11(b). Existing doors upgraded to FD20 where needed
  • Partitions enclosing the stair: REI 30 (30-minute) fire-resisting construction
  • Interlinked mains smoke detectors with battery standby — Grade D LD2 (BS 5839-6, §1.8–1.9)
  • No escape window required in the loft rooms — the protected stair is the means of escape

Alternative — open-plan with suppression (§2.23)

  • Sprinkler (or mist) protection to the open-plan area
  • REI 30 partition + E20 door separating the ground storey from the upper storeys
  • One first-storey escape window reachable via that door (≥0.33m² clear, ≥450mm each way, sill ≤1100mm — §2.10)
  • Cooking facilities separated from the open-plan area with REI 30 construction

FD30 is a common over-spec but is not the AD B minimum. All £ figures are indicative estimates — confirm scope with your building control body.