Loft Bathroom Calculator — Soil Pipe, Pump & Ventilation
Plan a loft bathroom with soil pipe routing, macerator pump requirements, Part F ventilation rates and waterproofing quantities.
Bathroom length
Bathroom width
110mm gravity soil pipe, or macerator (22mm discharge)
32mm waste pipe
40mm waste pipe
40mm waste, check floor loading
If gravity drainage not possible — WC macerator discharges 22mm
Your budget for reference (not a calculated estimate)
Next up: related pages
How We Calculate This
This calculator helps plan a loft bathroom by determining soil pipe routing, pump requirements, ventilation and waterproofing quantities.
Ventilation (Approved Document F 2021)
15 L/s intermittent extract (Table 1.1) or 8 L/s continuous MEV (Table 1.2). As an alternative, an openable window providing purge ventilation of at least 1/20 of the floor area (hinged/pivot opening ≥30°, Table 1.4) is acceptable.
Waterproofing / tanking
The floor is tanked in full. Walls in the wet zone (shower or bath) should be tanked to showerhead height (~2m) or full height per BS 5385-4 / The Tile Association wet-area guidance — a 300mm splash band is only sufficient on dry walls. This calculator tanks the floor plus one full-height wet wall (where there is a shower or bath) plus a 300mm splash band on the remaining perimeter.
Soil pipe and drainage
- Internal: 110mm gravity soil pipe boxed in within the loft
- External: 110mm gravity soil pipe down the outside wall
- WC macerator: a 22mm discharge pipe (e.g. Saniflo/Saniplus) where a gravity run is not practical. The 32mm size applies only to grey-water waste pumps (e.g. Sanivite), not to WC macerators
Indicative soil-pipe lengths shown are estimating assumptions — confirm against the actual route and drop to the connection point.
Frequently Asked Questions
Yes, a bathroom or en-suite is a common feature of loft conversions. The main challenges are routing the soil pipe (110mm for WC) to the existing drainage, providing adequate ventilation, and ensuring the floor structure can support the additional loads (especially a bath). Building Regulations Parts G, F and H apply.
A macerator pump (like Saniflo) is needed only if the WC is below the level of the nearest drainage connection, or if routing a full 110mm gravity soil pipe is impractical. WC macerators (Saniflo, Saniplus, Sanipro and similar) discharge through a small 22mm pipe, run horizontally up to around 50m on the entry-level unit or up to about 100m on a Saniplus, with a minimum 1:100 fall after any vertical lift. The 32mm discharge size applies to grey-water-only waste pumps (Sanivite/Sanispeed), not to WC macerators. Macerators add ongoing maintenance and noise considerations.
Part F requires a minimum extract rate of 15 L/s (intermittent) or 8 L/s (continuous MEV) for a bathroom. An openable window providing 1/20th of the floor area is acceptable as an alternative. An internal bathroom (no window) must have mechanical ventilation with a 15-minute overrun timer.
Yes. The floor and walls in wet zones (around shower, bath and basin) should be waterproofed using a tanking membrane, liquid applied waterproofing or sheet membrane before tiling. This prevents water penetrating the floor structure and causing damage to the ceiling below.
Internal routing boxes the soil pipe inside the loft space, running it down through the airing cupboard or built-in wardrobe to connect below. External routing takes the pipe down the outside wall — simpler but visible. Both must connect to the existing soil stack or drainage at a suitable point.
Related Calculators
Loft Party Wall Calculator
Calculate loft party wall Part E and fire-rated boarding with acoustic sealant.
Loft Boarding Calculator
Calculate loft boards, battens and fixings for loft storage flooring.
Loft Ladder Sizing Calculator
Calculate loft ladder length and opening size for your floor-to-floor height.
Was this calculator helpful?
Last updated: March 2026
Verified against UK standards · estimates only, confirm with your supplier.