Bathroom Spacing Calculator — Minimum Clearances & Layout
Check whether your bathroom dimensions meet minimum clearance requirements around WC, basin, bath and shower per UK building standards and Part M accessibility.
Internal room length in mm
Internal room width in mm
Applies the M4(1) WC access zone: 750mm front + at least 450mm each side of the WC centre line for head-on access (500mm preferred; the opposite side may reduce to 400mm only where access is oblique). Full M4(2)/M4(3) wheelchair turning space is not modelled
Inward-swing doors consume floor space
Leaf width. An 826mm leaf gives the 775mm clear opening that satisfies Part M M4(1); the M4(1) minimum clear opening itself is 750mm
Rule-of-thumb clear circulation width. BS 6465-2 activity spaces are typically ~700mm deep in front of appliances
Next up: related pages
How We Calculate This
This calculator checks whether your bathroom dimensions provide adequate clearance around each fixture based on UK building standards and Part M accessibility requirements.
The formula
Fixture footprint = (Width + 2 × Side clearance) × (Depth + Front clearance)
For a standard WC suite (700 × 500mm plan): (500 + 2 × 200) × (700 + 600) = 900 × 1300mm = 1.17 m². The calculator sums every fixture footprint and runs three checks: total area, room length against the deepest fixture-plus-front-clearance run, and room width against the widest fixture zone plus circulation. An inward door also reserves a quarter-circle swept area of π × W² ÷ 4 (0.46 m² for a 762mm leaf).
Appliance plan sizes & clearances
- WC suite: 700 × 500mm; 600mm activity space in front, ~200mm clear each side of the pan (Part M M4(1): 750mm front, at least 450mm either side of the WC centre line for head-on access, 500mm preferred — opposite side may reduce to 400mm only for oblique access)
- Wash basin: 700 × 600mm; ~700mm in front, ~100mm each side
- Bath: 1700 × 800mm; ~700mm access space along the open side
- Shower: 900 × 900mm enclosure; ~700mm in front of the opening
Appliance plan sizes follow BS 6465-2:2017 (space recommendations for sanitary appliances); the accessible WC zone follows Approved Document M Volume 1 (M4(1) visitable dwellings: 750mm front, 450mm either side of the WC centre line for head-on access). This is an indicative area-and-fit check — confirm any tight design with a scaled drawing.
Frequently Asked Questions
BS 6465-2 recommends an activity space of about 600mm deep in front of a WC pan (the standard used here), plus at least 200mm clear EACH SIDE OF THE PAN EDGE for use and cleaning. For a Part M M4(1) visitable WC, Approved Document M Vol 1 requires 750mm in front of the pan and, for head-on access, at least 450mm EITHER SIDE of the WC centre line (500mm preferred) — measured from the centre line, not clear of each edge. The opposite side may be reduced to 400mm only where access to the WC is oblique.
Part M of the Building Regulations (Access to and use of buildings) sets minimum accessibility standards. For dwellings, Part M Category 1 (M4(1) visitable) requires a WC with 750mm frontal clearance and, for head-on access, at least 450mm either side of the WC centre line (500mm preferred); only where access is oblique may the side opposite the approach reduce to 400mm. Categories M4(2) (accessible/adaptable) and M4(3) (wheelchair user) add larger zones and, for the wheelchair standard, a 1500mm turning space — this calculator models the M4(1) WC zone only, not the full M4(2)/M4(3) turning circle.
There is no absolute minimum bathroom size in UK Building Regulations, and BS 6465-2 deliberately gives appliance space recommendations rather than fixed room sizes to keep design flexible. As a real-world rule of thumb, a small en-suite with WC, basin and shower typically needs at least 1.2m x 1.7m (about 2 m²), and a standard family bathroom with bath at least 1.7m x 2.4m (about 4 m²) — figures that assume adjacent fixtures SHARE their activity spaces. This calculator's pass/fail test is intentionally more conservative: it SUMS each fixture's footprint plus clearance without sharing overlap, so a real ~4 m² family bathroom can still report FAILS here yet lay out perfectly well on a scaled drawing. Treat a FAILS as a prompt to plan the layout, not a verdict that the room is too small. These figures assume standard clearances, not Part M.
Building Regulations do not mandate door swing direction for standard bathrooms, but an outward-opening door saves space inside the room and is safer in an emergency (you can access someone who has collapsed). However, outward-opening doors require hallway clearance. Sliding or bi-fold doors are a good compromise for small bathrooms.
Allow roughly 200-250mm minimum between a WC and an adjacent basin (measured edge to edge, not centre lines), with 250-300mm preferred. BS 6465-2 ties the gap to cleaning and bin access (around 210mm), so a little over 200mm is the practical floor. For Part M layouts allow at least 300mm. To facilitate cleaning, BS 6465-2 also recommends a gap of at least 65mm between adjacent appliances.
Related Calculators
Was this calculator helpful?
Last updated: March 2026
Verified against UK standards · estimates only, confirm with your supplier.