Orangery Calculator — Columns, Lantern Roof & Glazing

Calculate orangery dimensions including brick columns, lantern roof area, glazing infill panels, front opening width and insulated flat roof perimeter.

How We Calculate This

This calculator estimates key dimensions and material quantities for an orangery based on overall plan size and configuration.

Roof split

Total roof area is divided into the lantern (glazed, central) and the flat roof perimeter (insulated, solid). As a new thermal element in an extension, the flat roof must meet a limiting U-value of 0.15 W/m²K (Approved Document L 2021, Volume 1, Table 4.2); the 0.16 W/m²K figure applies only to new-build dwellings (Table 4.1), not extensions. The insulation board area shown adds 10% to the flat-roof area for board cutting and upstand/overlap wastage at the lantern kerb and parapet.

Structure

Brick columns support the perimeter beam. The brick count uses 527 bricks per m³ of solid pier (from the UK coordinating brick size 225×112.5×75mm) plus a 10% cutting allowance. A structural steel or aluminium beam spans the front opening between columns; the "front opening width" output is the gross plan length only — the beam size and section must be designed by a structural engineer. Glazing panels fill the spaces between columns.

Frequently Asked Questions

Was this calculator helpful?

Last updated: March 2026

Verified against UK standards · estimates only, confirm with your supplier.