External Wall Fire Calculator

Determine external wall and cladding fire requirements based on building height AND use, per Approved Document B, Regulation 7(2) and the Building Safety Act 2022. The combustibility rules apply to residential 'relevant buildings' only.

Top floor surface to lowest ground level

Safety notice

Fire safety measures must satisfy Approved Document B and often need building control approval. Confirm the final specification with building control or a fire engineer before relying on it.

How We Calculate This

This calculator determines external wall fire requirements from building height and use, using the rules in Approved Document B and the combustible-materials ban in Regulation 7(2). The height-triggered combustibility rules apply only to residential “relevant buildings” — those containing a dwelling, an institution, or a room for residential purposes, plus hotels, hostels and boarding houses since 1 December 2022.

Residential relevant buildings

  • 18m or more: all external-wall materials Class A1 or A2-s1,d0 (non-combustible) — Regulation 7(2), subject only to the limited Reg 7(3) exemptions.
  • 11m or more: insulation and filler/core material Class A2-s1,d0 or better — ADB para 10.7 (not B-s3,d2).
  • Below 11m: no height-triggered class, but the boundary surface-spread rule still applies.

Offices, assembly and non-residential schools

Regulation 7(2)’s stricter statutory A1/A2-s1,d0 ban and the para 10.7 residential 11m rule do not apply to these uses. However, ADB para 10.6 applies to any building with a storey 18m or more, whatever its use: insulation and filler material must be Class A2-s3,d2 or better. Below 18m, the external wall is assessed via the general ADB external-fire-spread provisions (surface spread near the boundary per Table 10.1, cavity barriers, and material classification or a BS 8414 / BR 135 tested system).

Always applies

  • Boundary surface rule: any external surface less than 1000mm from a relevant boundary must be Class B-s3,d2 or better, at any height and any use.

Key standards

  • BS EN 13501-1: Reaction to fire classification
  • BS 8414 / BR 135: Large-scale external fire spread test
  • Regulation 7(2): Combustible-materials ban (residential relevant buildings ≥18m)
  • ADB para 10.6: A2-s3,d2 insulation/filler (any building ≥18m)
  • ADB para 10.7: A2-s1,d0 insulation/filler (residential ≥11m)