Trickle Vent Calculator
Calculate trickle ventilator requirements for UK Building Regulations Part F. Determine equivalent area (EA) needed per room and number of vents required.
How We Calculate This
This calculator determines trickle vent requirements based on Part F of UK Building Regulations.
The formula
Vents Needed = Total EA Required ÷ EA per Vent (rounded up)
- Habitable rooms & kitchens: 8000 mm² EA total (Part F 2021)
- Wet rooms: 4000 mm² EA total (Part F 2021)
- Standard slot vent: 2500 mm² EA each
- EA = Equivalent Area measuring airflow capacity