Roof Window Calculator

Calculate roof window sizes, costs and natural daylight contribution. Covers centre-pivot and top-hung VELUX-style windows with Part L U-value checking.

Number of roof windows

Used for the daylight estimate (one-fifth floor-area rule of thumb)

How We Calculate This

This calculator estimates roof window costs (supply, flashing and installation) and gives an indicative average daylight factor for the room.

The cost formula

Total = (Unit Price × Opening Multiplier × Glazing Multiplier × Qty) + Flashing + Installation

  • Electric operation adds ~60% to unit cost
  • Triple glazing adds ~35% to unit cost
  • Flashing kit ~£75 per window
  • The default £250 fitting figure is a baseline for an easy, good-access swap — increase “Install per Window” (£300-600+) for new openings, scaffolding or roof trimming, which is why a full market supply-and-fit is typically £900-1,500

Daylight factor

Uses the recognised one-fifth rule floor-area shorthand for the average daylight factor: DFav ≈ (1/5) × (glazed area ÷ floor area) × 100 — i.e. multiply the window-to-floor area ratio by 0.2. This rule of thumb (Littlefair, “Designing with Innovative Daylighting”, BRE 1996; CIB “Daylight Design Rules of Thumb”) estimates the average daylight factor from just window area and room floor area, which are the only daylighting inputs this tool collects; the 0.2 coefficient already embeds typical glazing transmittance and room surface reflectance.

It is a quick guide for a typical light-coloured, unobstructed room, not a compliance figure. The full BRE average daylight factor is DF = (Ag × τ × θ) ÷ (A × (1 − R²)), where A is the room’s total internal surface area (not floor area), τ the glazing transmittance (≈ 0.68 double / 0.60 triple), θ the visible-sky angle and R the mean surface reflectance — that needs full room dimensions, and external obstructions are assessed separately under the BRE BR 209 site-layout guidance, so a detailed assessment also accounts for obstructions and glazing-bar losses. The familiar adequacy targets (about 2% for kitchens, 1.5% for living rooms and 1% for bedrooms) came from BS 8206-2, which has since been withdrawn and superseded by BS EN 17037:2018 (the current standard assesses daylight via median/minimum daylight factor or climate-based target illuminance rather than the average daylight factor).