Part E Sound Calculator — Sound Insulation Requirements

Check a wall, floor or stair against the constructions Approved Document E lists as achieving the Part E standards, and see which table row applies.

How We Calculate This

This page is a specification check against Approved Document E, not a prediction. Pick the element, the building situation and the construction, and it reports whether Approved Document E lists that construction as one which should achieve the standard, which table row applies, and what restrictions and testing obligations go with it.

Why there is no predicted dB figure

Tables 1a and 1b are field values, measured in the finished building and written DnT,w + Ctr and L'nT,w. A laboratory Rw for the same element is a different quantity, and Approved Document E gives no way to convert one to the other. Comparing the two directly reads optimistically, in the direction that lets a construction look compliant and then fail on site. Para 0.5 avoids the problem altogether: Sections 2, 3, 4 and 6 name constructions which, if built correctly, should achieve the field values directly, so the check is like for like.

Separating versus internal elements

Separating walls, separating floors and stairs with a separating function sit under Requirement E1 and Tables 1a and 1b, and Regulation 41 requires them to be tested. New internal walls and floors within a dwelling sit under Requirement E2 and Table 2, which is a laboratory Rw of at least 40 dB and is not verified by testing on site (para 0.9). Read the Limits on application before assuming E2 applies at all: it does not reach an internal wall which contains a door, an en suite wall, or an existing wall or floor in a building subject to a material change of use.

Two things the tables do not cover

Para 0.8: Tables 1a and 1b are stated to be appropriate between spaces used for normal domestic purposes, and a higher standard may be required against a communal or non-domestic space, with the level depending on the noise generated there. Para 0.2 and Annex E: the Robust Details exemption from testing applies to new-build houses and buildings containing flats only, so a conversion, and any building of rooms for residential purposes, is tested under Regulation 41 either way.

Related reading: our Part E Wall & Floor Sound Reduction reference page sets out each construction Approved Document E lists with the paragraph it comes from, and the Robust Details code series currently published. It quotes no decibel figure per construction, because Approved Document E gives none and the Rw ranges it used to carry had no published source. Where a manufacturer does publish a laboratory Rw for a tested proprietary system, it is still a different quantity from the Table 1a and 1b field values and there is no way to convert between them.