Part B Fire Calculator — Escape Routes & Fire Resistance

Determine Part B fire safety requirements based on building height, purpose group and floor area including fire resistance period, means of escape and sprinkler requirements.

Height of the top floor above ground level, measured as AD B Diagram D6 shows

How We Calculate This

This calculator determines Approved Document B (Fire Safety) requirements from building parameters.

Fire resistance

The period is a lookup in Table B2 of Appendix B, which is identical in AD B Volume 1 and Volume 2: purpose group down the side, height of the top floor above ground across the top, plus two basement columns read on the depth of the lowest basement. Table B1 sets the performance criteria (R for loadbearing capacity, E for integrity, I for insulation) that go with the period. Where a building has a basement, Table B2 note * takes the higher of the basement period and the ground or upper storey period.

Means of escape

For buildings other than dwellings, travel distances come from AD B Volume 2 Table 2.1 and are given both for escape in one direction only and for escape in more than one direction. Exit widths come from para 2.18 and Table 2.3, and escape stair widths from Table 3.1. Dwellinghouses and flats are covered by AD B Volume 1 Sections 2 and 3 instead.

Working figures for this are collected in our Part B Fire Resistance Ratings Reference reference table.