Wall Removal Calculator

Calculate wall area, temporary support requirements (needles and props), RSJ sizing for the span, padstones, and making-good quantities for UK wall removal projects.

Total length of wall to remove

Floor to ceiling height

Construction type and thickness

Load-Bearing Wall

Load-bearing walls require RSJ support

Leave blank if removing entire wall

How We Calculate This

This calculator estimates the materials, temporary supports, and waste quantities for internal wall removal. It covers both load-bearing walls (requiring RSJ support) and non-load-bearing partition walls.

Calculation method

Wall volume: Length × height × thickness. One-brick walls (215mm) are the most common load-bearing internal walls in UK houses.

RSJ sizing: Indicative beam sizes are based on typical domestic floor loads (1.5 kN/m² imposed + dead loads) per BS EN 1991. The actual size must be confirmed by a structural engineer based on specific loading conditions.

Temporary support: Needles at 1.2-1.5m centres with Acrow props at each end. The number of prop pairs depends on needle count and load distribution.

Padstones: Two padstones required (one at each RSJ bearing point). Sized to spread the beam reaction over sufficient masonry area.

Frequently Asked Questions

Last updated: March 2026

All calculations are estimates. Verify with your supplier.