Passivhaus Criteria Calculator

Check your design against Passivhaus certification requirements

How We Calculate This

Enter your building's treated floor area, annual space heating demand, airtightness test result and primary energy demand. The calculator divides annual energy figures by the treated floor area to give kWh/m².a and compares each against the Passivhaus thresholds. The space-heating criterion passes if EITHER the annual demand is at most 15 kWh/m².a OR the optional peak heating load is at most 10 W/m² — only one need be met. To assess Plus or Premium, also enter the on-site renewable generation and the projected building footprint; generation is compared per m² of footprint (at least 60 for Plus, 120 for Premium).